Medical Lab Fully 5 Diff Auto Hematology Analyzer/Cbc Test Machine
Medical Lab Fully 5 Diff Auto Hematology Analyzer/Cbc Test Machine
Medical Lab Fully 5 Diff Auto Hematology Analyzer/Cbc Test Machine
Medical Lab Fully 5 Diff Auto Hematology Analyzer/Cbc Test Machine
Model
CNME030105E

Item specifics

Classification
Biochemical Apparatus
Type
Hematology Analyzer
Certification
CE, ISO13485
Group
All People
Weight
75kg
Test Mode
Cbc+5diff, Cbc

Product review

Description

Medical Lab Fully 5 Diff Auto Hematology Analyzer/Cbc Test Machine

Basic Info.
Model NO.
CNME030105E
Sampling Mode
Autoloader; Close Tube
Specification
Dimensions: 61 cm(L)x76cm(W)x61 cm(H)
Origin
China
Medical Lab Fully 5 diff Auto Hematology Analyzer/Cbc Test Machine
5 diff Auto Hematology Analyzer Features:
CBC+5DIFF mode CBC mode
28 Parameters, 2 Histograms, 2 Scattergrams
Auto-loader, 60 samples/hour
3-D Topographic Maps for WBC
Integral Titanium Incubation System
Laser Scatter Technology
Constant Linear Sheath Flow
Random Direction Tube Barcode Scanning Technology (Optional)

5 diff Auto Hematology Analyzer Technical Specification:
Principles
24 Regular Parameters:
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, LYM#, MON#, BAS#,
NEU%, LYM%, MON%, EOS#, EOS%, BAS%
4 Research Parameters:
ALY#, IG#, ALY%, IG%
2 Histograms, 2 Scattergrams
Parameters
Autoloader Mode: 60 Samples/hour
Close Tube Mode: 60 Samples/hour
Test Mode
CBC+5DIFF, CBC
Sampling Mode
Autoloader:
50 tubes position, random direction tube barcode scanning technology
Close Tube:
STAT prioriy, support both whole blood and capilary blood samples
Power Supply 
110V-240V, 50Hz/60Hz
Operation Environment
Temperature:15°C-30°C
Humidity:30%-85%
Data Storage Capacity
Up to 40,000 results including numeric and graphical information
Weight 
75KG
Dimension
61cm(L)*76cm(W)*61cm(H)
Use-friendly Software
Data Management
•100,000 results storage including histogram and scattergram
•Multi print format including self-defined format
•Mean, CV and SD values are calculated
•Statistics including Sample, QC and Calibration
•Sort by sample number, patient name, type, time frame etc.
Easy Maintenance
•Self-check during start up and shut down
•Tubing automatic maintenance
•Adjustable sleeping mode
Multi-warning System
Multi-warning System
•Reagent inventory check
•Abnormal original data warning
•Multi warning flags
System Setup
•Different levels of permission
•Different reference ranges determined by age and gender
LIS Interface
•LIS interface with HL7 protocol
More Options for your selection